--- title: "Quick Installation Guide - icom OS Routers" slug: "quick-installation-guide-en" tags: ["Router", "SCR", "MIRO", "Quick Installation Guide", "MRX", "ECR"] updated: 2026-08-18T09:51:09Z published: 2026-08-18T09:51:09Z canonical: "docs.insys-icom.com/quick-installation-guide-en" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.insys-icom.com/llms.txt > Use this file to discover all available pages before exploring further. # Quick Installation Guide - icom OS Routers INSYS routers are easy to install and feature a startup wizard that makes it easy to make them ready for operation. Proceed as follows to bring your router into service: ## Making the Internet connection (WAN) 1. Stellen Sie die Internet-Verbindung (WAN) je nach Technologie (Mobilfunk, LAN, DSL, Fiber) her. Siehe folgende Darstellungen. **LAN - MRX, MRX.neo, MOROS.neo, SCR, ECR, MIRO** ![](https://cdn.document360.io/c690fe99-a3eb-474c-a449-c2c75e5df119/Images/Documentation/image(599).png) 1. Connect the network that is used to establish the Internet connection to the router: MRX.neo/MOROS.neo: **ETH 4** MRX/MRO: **ETH 5** ECR/SCR/MIRO: **ETH 2** **Cellular radio - MRX.neo, MOROS.neo** ![](https://cdn.document360.io/c690fe99-a3eb-474c-a449-c2c75e5df119/Images/Documentation/image(600).png) 1. Insert the SIM card in the SIM tray (**SIM 1**) and insert it into the device. 2. Connect a cellular antenna (**LTE 1**). **Cellular radio - MRX, ECR, SCR, MIRO** ![](https://cdn.document360.io/c690fe99-a3eb-474c-a449-c2c75e5df119/Images/Documentation/image(601).png) 1. Insert a SIM card (**SIM 1**). 2. Connect a cellular antenna (**LTE 1**). **DSL/Fiber - MRX, MRX.neo** ![](https://cdn.document360.io/c690fe99-a3eb-474c-a449-c2c75e5df119/Images/Documentation/image(602).png) 1. Connect the DSL connection line to the **VDSL/ADSL** socket or 2. connect the glass fiber line and the SFP module to the **SFP 1** socket. ## Connecting the power supply 1. Connect supply voltage (12 V … 24 V DC) to the router. Connect the positive lead to the V+ or VIN terminals (depending on the router) and the negative lead to the V- or GND terminals on the connector. > [!WARNING] > Please note for routers of the **MRX.neo** series! > > Connect the power supply only to the connector of the card in Slot 1. The **MRX.neo** does not support power supply via cards in other slots. ## Making the configuration connection **Configuration via Ethernet** 1. Connect the PC used for configuration to the router (**green cable** in the illustrations above in the **ETH 1** socket). **Configuration via WiFi** WiFi routers of the series **MRX.neo** and **MOROS.neo** permit a commissioning without Ethernet connection. 1. Connect a WiFi antenna. 2. Briefly press the **WLAN** button. The **WLAN** LED flashes orange. 3. Connect your configuration PC to the WLAN with the SSID **icom_os_…** followed by the serial number of the router. Once the connection is established, the LED **WLAN** lights up **green**. > [!WARNING] > Temporary available open WiFi network! > > The network activated using the WLAN button is unencrypted and does not require a password. It is intended solely for commissioning purposes and will switch off automatically after 120 minutes if the configuration is not completed before then. Please only activate it for a short period and in a controlled environment. 1. Enter https://insys.icom in the address bar of the browser (default: [https://192.168.1.1](https://192.168.1.1/)). A DHCP client must be active on the PC. Otherwise, enable the DHCP client or configure a static IP. ## Configuring the router A router in default settings will open with a splash screen that provides three options for configuring the router. We recommend using the [Startup wizard](/kb/docs/quickstart-wizard-en) for commissioning. > [!NOTE] > Router with outdated firmware? > > If your router has an outdated firmware, no welcome screen will be displayed. If the router is in [default settings](/kb/docs/en/resetting-to-defaults-en), you will be taken to the [user interface](/kb/docs/en/new-and-classic-user-interface-en) after entering the standard credentials (user name: *insys*, password: *icom*). ![](https://cdn.document360.io/c690fe99-a3eb-474c-a449-c2c75e5df119/Images/Documentation/image(9).png) The **Startup wizard** starts an assisted configuration that enables you to set up the router for - System time synchronisation - User authentication - Internet (WAN) connection - VPN connection (icom Connectivity Suite or custom OpenVPN or IPsec) - Local network connection - icom Router Management and make the router ready for operation. **Manual configuration** enables you to configure the router manually for the specific needs of your application. **Upload settings and files** enables you to upload files that contain a complete configuration, updated firmware, certificates or containers. The serial number can be taken from the label on the router or its menu item *Status* → *Dashboard*. Standard IP address: https://192.168.1.1; login depending on configuration; default for earlier firmware versions: *User name*: **insys**, *Password*: **icom**